BP OIL CO -- GASOLINE, BP REGULAR UNLEADED -- 9130-00N082378
===================== Product Identification ===================== Product ID:GASOLINE, BP REGULAR UNLEADED MSDS Date:04/25/1995 FSC:9130 NIIN:00N082378 === Responsible Party === Company Name:BP OIL CO Address:200 PUBLIC SQUARE City:CLEVELAND State:OH ZIP:44114-2375 Country:US Info Phone Num:800-321-8642; 216-586-8023 Emergency Phone Num:800-424-9300(CHEMTREC) CAGE:0D3L4 === Contractor Identification === Company Name:BP OIL CO Address:200 PUBLIC SQ City:CLEVELAND State:OH ZIP:44114-2375 Country:US Phone:216-586-4219/216-586-6499 CAGE:0D3L4 Company Name:BP OIL COMPANY Address:200 PUBLIC SQ Box:City:CLEVELAND State:OH ZIP:44114-2375 Country:US Phone:216-586-8023 CAGE:82250 ============= Composition/Information on Ingredients ============= Ingred Name:GASOLINE (MAY CONTAIN INGREDIENTS 2-11) % WT: 99.99-100 CAS:8006-61-9 RTECS #:LX3300000 Fraction by Wt: <100% OSHA PEL:300 PPM ACGIH TLV:300 PPM; 500 STEL Ingred Name:TOLUENE (SARA 313) (CERCLA) CAS:108-88-3 RTECS #:XS5250000 Fraction by Wt: 10-12% OSHA PEL:200 PPM ACGIH TLV:50 PPM, S EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:PENTANE CAS:109-66-0 RTECS #:RZ9450000 Fraction by Wt: 9-11% OSHA PEL:1000 PPM ACGIH TLV:600 PPM; 750 STEL Ingred Name:XYLENE (SARA 313) (CERCLA) CAS:1330-20-7 RTECS #:ZE2100000 Fraction by Wt: 6-10% OSHA PEL:100 PPM ACGIH TLV:100 PPM; 150 STEL EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:HEXANE (CERCLA) CAS:110-54-3 RTECS #:MN9275000 Fraction by Wt: 8-10% OSHA PEL:500 PPM ACGIH TLV:50 PPM EPA Rpt Qty:1 LB DOT Rpt Qty:1 LB Ingred Name:HEPTANE (C7 & HIGHER) CAS:142-82-5 RTECS #:MI7700000 Fraction by Wt: 6-8% OSHA PEL:500 PPM ACGIH TLV:400 PPM; 500 STEL Ingred Name:BUTANE CAS:106-97-8 RTECS #:EJ4200000 Fraction by Wt: 4-6% OSHA PEL:800 PPM ACGIH TLV:800 PPM Ingred Name:BENZENE (SARA 313) (CERCLA) CAS:71-43-2 RTECS #:CY1400000 Fraction by Wt: 0-3% OSHA PEL:N/K ACGIH TLV:10 PPM EPA Rpt Qty:10 LBS DOT Rpt Qty:10 LBS Ingred Name:BENZENE, 1,2,4-TRIMETHYL-; (1,2,4-TRIMETHYLBENZENE) (SARA 313) CAS:95-63-6 RTECS #:DC3325000 Fraction by Wt: 0-3% OSHA PEL:25 PPM ACGIH TLV:25 PPM Ingred Name:BENZENE, ETHYL-; (ETHYLBENZENE) (SARA 313) CAS:100-41-4 RTECS #:DA0700000 Fraction by Wt: 0-2% OSHA PEL:100 PPM ACGIH TLV:100 PPM; 125 STEL EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:CYCLOHEXANE (SARA 313) (CERCLA) CAS:110-82-7 RTECS #:GU6300000 Fraction by Wt: 1% OSHA PEL:300 PPM ACGIH TLV:300 PPM EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:SUPDAT: EXPLODE IN HEAT OF FIRE. IRRIT OR TOX SUBSTANCES MAY BE EMITTED UPON THERMAL DECOMP. RTECS #:9999999ZZ Ingred Name:EXPLAN OF CARCIN: ANNUAL REPORT ON CARCINS: 1994:KNOWN TO BE CARCIN. OSHA REGULATED: CFR 29 1910.1028. RTECS #:9999999ZZ Ingred Name:EFTS OF OVEREXP:INHAL:MAY CAUSE RESP TRACT IRRIT & CNS SYMPS SIMILAR TO INGEST. MAY CAUSE IRREGULAR HEART RHYTHM(ING 15) RTECS #:9999999ZZ Ingred Name:ING 14:& BEHAVIORAL CHG. CHRONIC:TOLUENE APPEARS ON NAVY LIST OF OCCUP CHEM REPRO HAZS. SEEK CONSULT FROM APPROP(ING 16) RTECS #:9999999ZZ Ingred Name:ING 15: HLTH PROFESSIONALS CONCERNING LATEST HAZ LIST & SAFE HNDLG & EXPOS INFO . SOLV "SNIFFING" OR (ING 17) RTECS #:9999999ZZ Ingred Name:ING 16:INTENTIONAL PRLNGD OVEREXP TO HIGH LEVELS OF SOLV VAPS CAN PRDCE ABNORM BEHAVIOR, CONVLS, HALLUCINATIONS,(ING 18) RTECS #:9999999ZZ Ingred Name:ING 17: DELIRIUM, NERVOUS SYS DMG & SUDDEN DEATH. CONTACT NEHC FOR MORE INFO ON HEALTH HAZARDS . RTECS #:9999999ZZ Ingred Name:FIRST AID: NOT BRTHG, ENSURE CLEAR AIRWAY & START CPR. IF BRTHG IS DFCLT, ADMIN O*2 IF AVAIL. MONITOR CLOSELY. (ING 20) RTECS #:9999999ZZ Ingred Name:ING 19: GET IMMED MED ATTN. NOTES TO MD: INGEST:MOST IMPORTANT RISK TO ASSESS IS EXTENT OF ASPIR INTO LUNGS (ING 21) RTECS #:9999999ZZ Ingred Name:ING 20: SINCE ACUTE CHEM PNEUMIT CAN RAPIDLY PROGRESS TO RESP FAILURE. GASPING, COUGH & CHOKING ARE PRESUMPTIVE (ING 22) RTECS #:9999999ZZ Ingred Name:ING 21: EVID OF ASPIR. SUGGEST ALL PATIENTS SUSPECTED OF HYDROCARB ASPIR HAVE BASE LINE CHEST X-RAY. CONSIDER (ING 23) RTECS #:9999999ZZ Ingred Name:ING 22: IMMED HOSPITALIZATION FOR ASYMPTOMATIC CHILDREN W/ABNORM CHEST X-RAY, OBTUNDED OR HYPOXIC PATIENTS, (ING 24) RTECS #:9999999ZZ Ingred Name:ING 23: INTENTIONAL/MASSIVE INGESTS & PATIENTS W/ABNORM CHEST X-RAYS W/CLINICALLY SIGNIFICANT PULM DISEASE. GI (ING 25) RTECS #:9999999ZZ Ingred Name:ING 24: SYMPS ARE USUALLY MINOR & PATHOLOGICAL CHGS OF LIVER & KIDNEY REPORTED UNCOMMON IN ACUTE INTOXICATIONS. RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES Health Hazards Acute and Chronic:INGEST:ASPIR INTO LUNGS MAY CAUSE PNEUMIT. MAY CAUSE GI DISTURBS. SYMPS INCL IRRIT, NAUS, VOMIT & DIARR. MAY CAUSE HARMFUL CNS EFTS; MAY INCL EXCITATION, EUPHORIA, HDCH, DIZZ, DROW, BLURRED VISION, FA TG, TREMORS, CONVLS, UNCON, COMA, RESP ARREST & DEATH. SKIN:SLIGHT IRRIT. RPTD/PRLNGD CNTCT MAY CAUSE (EFTS OF OVEREXP) Explanation of Carcinogenicity:GASOLINE: IARC MONO, VOL 45, PG 159, 1989:GROUP 2B. BENZENE: IARC MONO, VOL 7, PG 120, 1987:GROUP 1. NTP 7TH (ING 13) Effects of Overexposure:HLTH HAZ: DEFAT, REDNESS, ITCH, INFLAM, CRACKING & POSS BURNS & SECONDARY INFECTION. HIGH PRESS SKIN INJECTIONS ARE SERIOUS MED EMERS. INJURY MAY NOT APPEAR SERIOUS AT FIRST; W/IN FEW HRS, TISS BECOME S SWOLLEN, DISCOLORED & EXTREMELY PAINFUL. EYES:MAY CAUSE IRRIT, REDNESS, PAIN, BLURRED VISION, LACRIM & CONJ. (ING 14) Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:INGEST:DO NOT INDUCE VOMIT; ASPIR DANGER. GET IMMED MED ATTN. IF SPONT VOMIT OCCURS, MONITOR FOR BRTHG DFCLTY. SKIN:REMOVE CONTAMD CLTHG IMMED. WASH AREA W/SOAP & WATER. GET MED ATTN IF IRRIT PERSISTS . HIGH PRESS SKIN INJECTIONS REQ IMMED MED CARE. EYES:FLUSH IMMED W/LG AMTS OF WATER FOR AT LST 15 MIN. HOLD LIDS AWAY FROM EYEBALL. GET MED ATTN IF IRRIT RSLTS. INHAL:REMOVE FROM EXPOS. IF (ING 19) ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:-35F,-37C Lower Limits:1.4% Upper Limits:7.6% Extinguishing Media:USE DRY CHEMICAL, ALCOHOL FOAM, ALL PURPOSE AFFF OR CARBON DIOXIDE TO EXTINGUISH FIRE. Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . WATER MAY BE INEFTIVE BUT SHOULD BE USED TO COOL FIRE-EXPOS CNTNRS, STRUCTURES & TO PROTECT PERS. IF (SUPDAT) Unusual Fire/Explosion Hazard:DANGEROUS WHEN EXPOS TO HEAT/FLAME. VAPS FORM FLAM/EXPLO MIXS W/AIR AT ROOM TEMP. VAP/GAS MAY SPREAD TO DISTANT IGNIT SOURCE & FLASH BACK. VAPS MAY CONC(SUPDAT) ================== Accidental Release Measures ================== Spill Release Procedures:SHUT OFF IGNIT SOURCE. STOP LEAK IF W/OUT RISK. WATER SPRAY MAY REDUCE VAP BUT MAY NOT PVNT IGNIT IN CLSD SPACES. SM SPILL:TAKE UP W/NONCOMBUST ABSORB & PLACE INTO CNTNRS. LG SPILL:DIKE FAR AHEAD OF L IQ SPILL. CNTCT NEHC FOR MORE INFO . Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE ONLY IN APPRVD, CLEARLY LABELED CNTNRS (NEVER IN GLASS/UNAPPRVD PLASTIC CNTNRS); TIGHTLY CLSD IN COOL, DRY, ISOLATED, WELL-VENTD AREA. Other Precautions:DO NOT SIPHON PROD BY MOUTH. USE ONLY AS MOTOR FUEL; NOT FOR CLEANING, PRESS APPLIANCE FUEL/ANY OTHER USE. KEEP OUT OF REACH OF CHILDREN. EMPTY CNTNRS MAY CNTN TOX, FLAM, COMBUST, EXPLO RESIDUE/VAPS. CONTACT NEHC FOR MORE INFO . ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF EXPOS LIMS ARE EXCEEDED OR IRRIT IS EXPERIENCED, NIOSH APPRVD RESP PROT SHOULD BE WORN. VENT & OTHER FORMS OF ENGINEERING CTS ARE OFTEN PREF MEANS FOR CONTROLLING CHEM EXPOS. RESP PROT MAY BE NEEDE D FOR NON-ROUTINE OR EMER SITUATIONS. Ventilation:NONE SPECIFIED BY MANUFACTURER. Protective Gloves:IMPERVIOUS GLOVES. Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES . Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . AVOID SKIN CONTACT. WEAR PROT CLTHG. DO NOT WEAR CNTCT LENSES. Work Hygienic Practices:WASH HANDS IF IN CNTCT W/MATL. USE GOOD PERSONAL HYGIENE. WEAR REGULARLY CLEANED WORK CLTHG. SHOWER & CHANGE AFTER WORK. Supplemental Safety and Health FIRE FIGHT PROC: LEAK/SPILL HAS NOT IGNITED, VENT AREA & USE WATER SPRAY TO DISPERSE GAS/VAP & PROTECT PERS. USE WATER TO DULUTE SPILLS & FLUSH THEM AWAY FROM IGNIT SOURCE. DO NOT FLUSH DOWN PUBLIC SE WERS/OTHER DRAIN SYS. EXPLO HAZ: IN CONFINED AREAS. RUNOFF TO SEWER MAY CAUSE FIRE/EXPLO HAZ. CNTNRS MAY (ING 12) ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:>80F,>27C Vapor Pres:760 @ 100F Vapor Density:1.2 Spec Gravity:0.72-0.74 Evaporation Rate & Reference:>1 (H*2O=1) Solubility in Water:NEGLIGIBLE Appearance and Odor:CLEAR LIQUID WITH A STRONG HYDROCARBON ODOR. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES AVOID CONTACT WITH STRONG OXIDIZERS. Stability Condition to Avoid:STABLE UNDER CONDITIONS OF NORMAL USE. Hazardous Decomposition Products:COMBUSTION MAY PRODUCE CARBON MONOXIDE, CARBON DIOXIDE AND REACTIVE HYDROCARBONS. ==================== Disposal Considerations ==================== Waste Disposal Methods:CHECK 40 CFR 261 TO DETERMINE WHETHER THIS SUBSTANCE IS HAZARDOUS WASTE. TRANSPORTATION, STORAGE, TREATMENT & DISPOSAL OF THIS WASTE MATERIAL MUST BE CONDUCTED IN COMPLIANCE W/ALL APPLIC FEDERAL, STAT E & LOCAL REGS. FOR MORE INFO CNTCT NEHC . Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.