AIRGAS -- OXYGEN -- 6830-00-656-1603
=====================  Product Identification  =====================

Product ID:OXYGEN
MSDS Date:05/01/1990
FSC:6830
NIIN:00-656-1603
=== Responsible Party ===
Company Name:AIRGAS
Address:100 MALSONFOFO ROAD
City:RADNOR
State:PA
ZIP:19067
Country:US
Info Phone Num:215-687-5253
Emergency Phone Num:215-687-5253
CAGE:AIRGA
=== Contractor Identification ===
Company Name:AIRGAS
Address:100 MATSONFORD ROAD, 5 RADNOR CORP CNTR
City:RADNOR
State:PA
ZIP:19087
Country:US
Phone:215-687-5253
CAGE:AIRGA

=============  Composition/Information on Ingredients  =============

Ingred Name:OXYGEN
CAS:7782-44-7
RTECS #:RS2060000
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:BREATH HIGH CONC(>75MOLAR %)CAUSES
    SYMPTOMS OF HYPEROXIA WHICH INCLUDES
    CRAMPS,NAU,DIZZ,HYPOTHERMIA,AMBLYOPIA,RESP
    DIFFICULTIES,BRADYCARDIA,FAINTING SPELLS,CONVULSIONS CAPABLE OF
    LEADING TO DEATH.PHYP EROXIA PROPERTY LEADS TO PNEUMONIA.INFLAMM OF
    ORG MATTER IN BODY W/CONC 25-75 MOLAR %.
Explanation of Carcinogenicity:PER MSDS:OXYGEN NOT LISTED IN
    IARC/NTP/OSHA AS CARCINOGEN OR POTENTIAL CARCINOGEN.
Effects of Overexposure:SEE HEALTH HAZARDS ABOVE.
Medical Cond Aggravated by Exposure:PERSONS IN ILL HEALTH WHERE SUCH
    ILLNESS WOULD BE AGGRAVATED BY EXPO TO OXYGEN SHOULD NOT BE ALLOWED
    TO W/OR HNDLG THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:PROMPT MED ATTN MANDATORY IN ALL CASES OF OVEREXPO.RESCUE
    PERSONS SHOULD BE COGNIZANT OF EXTREME FIRE HAZ ASSOC W/OXY RICH
    ATMS.ASSIST CONSC PERSON TO UNCONTAMIN AREA.BREATH FRESH AIR.KEEP
    WARM/QUIET. INFORM DR VICTIM EXPERIENCE HYPEROXIA.REMOVE UNCONSC
    PERSON TO UNCONTAMIN AREA.GIVE ASSIST RESP.RESTORE BREATHING TREAT
    AS ABOVE.CONT TREATMENT SHOULD BE SYMPTOMATIC/SUPPORTIVE.

=====================  Fire Fighting Measures  =====================

Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:IF POSSIBLE STOP FLOW OF OXYGEN WHICH IS
    SUPPORTING FIRE.CYLINDERS INVOLVED IN FIRE SAFELY RELOCATE OR KEEP
    COOL WITH WATER SPRAY.VIGOROUSLY ACCELERATES COMBUST
Unusual Fire/Explosion Hazard:OXYGEN VIGOROUSLY ACCELERATES
    COMBUST.CONTACT W/ALL FLAMM MATLS SHOULD BE AVOIDED.SOME MATLS
    WHICH ARE NOT FLAMM IN AIR WILL BURN IN PURE OXY/OXY RICH ATMS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE ALL PERSONNEL.SUE APPROPRIATE
    PROTECTIVE EQPMT.LEAK IN USER'S EQPMT BE CERTAIN TO PURGE PIPING
    W/INERT GAS PRIOR TO REPAIRS.LEAK IN CNTNR/CNTNR VALVE CONTACT
    CLOSEST SUPPLIER LOCATION/EMERG P HONE # LISTED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE IN WELL VENTI AREA.VLAVE PROT
    CAPS/OUTLET PLUGS REMAIN IN PLACE UNLESS PIPED TO USE PT.DON'T
    DRAG/SLIDE/ROLL;USE HAND TRUCK.PROTECT CYL FRM PHY DG
Other Precautions:USE PRESSURE RED REG WHEN CONNECTING CYL TO <3000PSIG
    PIPING/SYS.DON'T HEAT CYL TO INCR PRESSURE/DISCHARGE.DON'T USE
    SUBSTITUTE FOR COMPRESSED AIR IN PNEUMATIC EQPMT CONTAINS FLAMM
    LUBRICANTS.CLEAN FO R OXY SERVICE.SECURE UPRIGHT WHEN MOVING

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:LOCAL EXHAUST:TO PREVENT ACCUMULATION ABOVE 25MOLAR %.
Protective Gloves:AS REQUIRED, ANY MATERIAL.
Eye Protection:SAFETY GOGGLES OR GLASSES.
Other Protective Equipment:SAFETY SHOES, SAFETY SHOWER.
Work Hygienic Practices:CONSULT COMPRESSED GAS ASSOC PAMPHLETS
    P-1,P-14,G-4,G-4.1.
Supplemental Safety and Health
INCOMPAT:SILICON ALLOYS,MONEL,INCONEL,BERYLLIUM.PB/AG,PB/SN ALLOYS GOOD
    GASKETING MATLS.TEFLON/KELF AREA PREFERRED NONMETAL GASKETS.IGN
    TEMP OF METALS/NONMETALS IN PURE OXY SERVICE DECR W/INCR OXY PRE
    SSURE.

==================  Physical/Chemical Properties  ==================

HCC:G4
Boiling Pt:B.P. Text:-297F,-183C
Melt/Freeze Pt:M.P/F.P Text:-362F,-219C
Decomp Temp:Decomp Text:NP
Vapor Pres:>CRIT TENP
Vapor Density:.0828LB/F3
Spec Gravity:1.11 @70F
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:SLIGHLTY.
Appearance and Odor:COLORLESS, ODORLESS GAS.
Percent Volatiles by Volume:NP
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALL FLAMM MATL.LOW PRESSURE USE CARBON STEELS,LOW ALLOY STEEL;HI
    PRESSURE SS,CU/CU ALLOY,NI/NI ALLOY,BRASS,BRONZE,(SUPP)
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DON'T ATTEMPT TO DIPSO OF WASTE/UNUSED
    QUANT.RETURN IN SHIPPING CNTNR PROPERLY LABEL/VALVE OUTLET
    PULGS/CAPS SECURED/VALVE PROTECTION CAP IN PLACE TO SUPPLIER.EMERG
    DISPO ASSIST CONTACT SUPPLIER/EMERG  PHONE #LISTED.FILL ONLY BY
    QUAL COMPRESS GAS PROD

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.